Spare part FU2431-A2524-D1207-F10140-G4-K39-N1220 LABOM

on request

We supply the original spare part FU2431-A2524-D1207-F10140-G4-K39-N1220 from LABOM worldwide and look forward to your enquiry.

Free spare parts enquiry

  • Guaranteed response
  • free of charge & without obligation
  • Expert review

Information for spare part FU2431-A2524-D1207-F10140-G4-K39-N1220

with switch contact and capillary see data sheet T3-029 FU 2 case: NS 100 43 case design: IP 66, bottom connection 1 explosion protection: with Ex-protection A2 accuracy class: see data sheet 524 nominal range: 0...+100°C D12 process connection: shanks rotating 07 nominal width: G 1/2 F10 temperature detecting element: ø 10 mm 140 insertion length L1: 140 mm G4 mounting: with wall bracket, aluminium K3 capillary: material stainless steel 9 length of capillary [m]: 3,00 N1 switch contact: inductive contact with safety initiator (SN) 220 switch function: 2 x max. open contact Ex desing for inductive contact device: P+F SJ2-SN / SJ3.5-SN PTB 00 ATEX 2049X II 2 G Ex ia IIC T4/T5/T6 Gb Ex design (ATEX) for mechanical instruments: II 2G Ex h IIC T1...T6 Gb X, II 2D Ex h IIIC Txx°C Db X Please pay attention to the application conditions, which can be taken from the data sheet and the ex-safety instructions XA_005 and XA_014. Temperature limits might be changed with implementation of EN ISO 80079-36:2016 and EN ISO 80079-37:2016 valid from 01.11.2019. electrical connection: connection plug with cable gland M20 x 1.5 and removable test cover, mat. Macrolon

Brand / Manufacturer LABOM
Article number FU2431-A2524-D1207-F10140-G4-K39-N1220
Description Gas expansion thermometer
KCCO Article number 10081052
+49 (0)511 89 88 09 0
Spare parts enquiry