We supply the original spare part CE6120-A1058-K1010-T110-H1 from LABOM worldwide and look forward to your enquiry.
design: flush mounted diaphragm, with temperature decoupler Ex-protection: without pressure sensor: piezoresistive for gauge pressure measuring range 0...10 bar, overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. process connection: threaded connection nominal width: G1/2 B with O-ring and sealing washer gasket material: NBR electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A), IP65 output signal: 4...20 mA, 2-wire technology
Brand / Manufacturer | LABOM |
Article number | CE6120-A1058-K1010-T110-H1 |
Description | Compact pressure transmitter for general applications acc. to data sheet d4-020-1 |
KCCO Article number | 10086384 |