Wir liefern das Originalersatzteil 7D2C40-AAACCAAAAAD2SKA1+D9LK von E+H /Endress+Hauser weltweit und freuen uns auf Ihre Anfrage.
Order code description AA Approval: Non-hazardous area A Output; Input: 4-20mA HART C Display; Operation: SD02 4-line; push buttons + data backup function C Housing: GT20 dual compartment,alu,coated,compact A Cable, Remote Version: Not used A Electrical Connection: Gland M20 AA Sensor Version; DSC-Sensor; Meas. Tube: Volume; 316L; 316L -40...+260oC/-40...+500oF A DSC-Sensor Seal: Graphite, -200oC… +400oC, -328oF…752oF D2S Process Connection: PN40, EN1092-1-B1 K Calibration Flow: 0.75% volume 3-point A1 Device Model: 1 D9 >>Customized Parameterization: 71201503 Customer-specific parameter setting for Promag/Prowirl/Prosonic 93C/ Prosonic 92F only from DN150 till DN300 /Dosimag, all dimensions. LK >>Additional Approval: PED Cat.III Details Curr. output 1 Volume flow Select medium Steam Current span 4...20 mA NAMUR 4 mA value 0,00000 m3/h 20 mA value 307,00000 m3/h Failsafe mode current output Max. Operating temperature 20,000 °C Damping output 1 2,00000 s Display Format display 1 value, max. size Value 1 display Volume flow Value 2 display None Value 3 display None Value 4 display None Display damping 0,00000 s Totalizer 1 Unit m3 Failure mode Stop Totalizer 2 Unit kg Failure mode Stop Totalizer 3 Unit Nm3 Failure mode Stop
Marke / Hersteller | E+H /Endress+Hauser |
Hersteller-Teilenummer | 7D2C40-AAACCAAAAAD2SKA1+D9LK |
Beschreibung | Vortex flowmeter |
Hersteller-Artikelnummer | 7D2C40-1976/0 |
KCCO-Artikelnummer | 16001194 |