We supply the original spare part 5W4C1F-AAALHM0AUD3K0A+AACA from E+H /Endress+Hauser worldwide and look forward to your enquiry.
Order code description AA Approval: Non-hazardous area A Design: **Insertion length short ISO/DVGW until DN400, DN450-2000 1:1 L Power Supply: 100-240VAC/24VAC/DC H Output; Input: 4-20mA HART, pulse/freq./switch output M Housing: Compact, Polycarbonate 0 Cable, Remote Version: Not used A Electrical Connection: Gland M20 U Liner: Polyurethane D3K Process Connection: PN16, carbon steel, flange EN1092-1 0 Electrodes: 1.4435/316L A Calibration Flow: 0.5% AA >Operation Language Display: English CA >>Sensor Option: IP66/67, Type 4X, fully welded corrosion protection EN ISO 12944 C5-M Details Format display 1 value, max. size Value 1 display Volume flow Value 2 display None Value 3 display None Value 4 display None Display damping 0,00000 s Totalizer 1 Unit m3 Operating mode totalizer Net flow total Failure mode Stop Totalizer 2 Unit m3 Operating mode totalizer Net flow total Failure mode Stop Totalizer 3 Unit m3 Operating mode totalizer Net flow total Failure mode Stop Curr. output 1 Volume flow Current span 4...20 mA NAMUR Value 0/4 mA 0,00000 m3/h Value 20 mA 150,00000 m3/h Failsafe mode current output Max. Damping output 1 1,00000 s Operating mode Pulse Assign pulse output Volume flow Pulse value (per pulse) 0,02500 m3 Pulse width 100,000 ms Failsafe mode pulse output No pulses
Brand / Manufacturer | E+H /Endress+Hauser |
Article number | 5W4C1F-AAALHM0AUD3K0A+AACA |
Description | Electromagnetic flowmeter |
Manufacturer Part Number | 5W4C1F-DC90/0 |
KCCO Article number | 10108989 |